Immunoassay Analyzer Pointcare Reader Vet1i

Based on fluorescent lateral chromatography assay, Pointcare Reader Vet1i Immunoassay Analyzer provides quantitative in-vitro determination of clinical immunoassay analytes in whole blood, plasma (EDTA anticoagulant), or serum. The entire analysis requires 2μL of sample and is capable of providing results in 5 minutes.

Sales Support

international_sales@mnchip.com
WhatsApp: +86 181 0216 7085

Feature & Benefit

Accuracy
Wide dynamic range, accuracy comparable to reference laboratories, excellent repeatability, help you diagnose and treat patients confidently.
Quantitative
Test accurately quantify the concentration of analytes in blood sample.
Optical
Technology Improved fluorescence optical module for high sensitive diagnosis.
Measurement
Modes single, multi-mode, QC test and review (save results) mode.

Four simple steps
Fully automated system, the entire analysis requires 4-step operation.
Speed
5 minutes or so to complete the entire process from sample to output results, to help you quickly obtain comprehensive and accurate test results, reduce patient waiting time, and improve patient satisfaction.
Highly
Integrated compact, space-saving and portable design enables you to use this analyzer anywhere and anytime in various environments.

Reagent

Pointcare Reader Vet1i Immunoassay Analyzer is an in-vitro diagnostic device that measures the concentration of analytes, contained in whole blood, plasma (EDTA anticoagulant), or serum, in quantitative ways. The entire analysis requires 2μL of sample and is capable of providing results in 5 minutes.

fSAA Fluorenscence Quantitative Test Kit

cCRP Fluorenscence Quantitative Test Kit

FPV-Ab Fluorenscence Quantitative Test Kit

FHV-Ab Fluorenscence Quantitative Test Kit

FCV-Ab Fluorenscence Quantitative Test Kit

CPV-Ab Fluorenscence Quantitative Test Kit

CDV-Ab Fluorenscence Quantitative Test Kit

1 Test/Disc 10 Discs/Box

Step

add 2μl sample in the diluent tube.

slightly invert the diluent tube 5 or 6 times.

add 100 μl mixture into the sample port.

insert the test kit.

Specification

Dimensions: 210mm (L)*125mm (W)*175mm (H)
Weight: 1.3 kg (2.87 lbs)

Sample Type: Serum/Plasma (cCRP/fSAA: Whole blood/Serum/Plasma)
Sample Size: 0-640IU/L (cCRP: 0-200mg/L; fSAA: 0-300mg/L.)
Test Time: 5 minutes

Quality Control Features: Built-in real-time Quality Control (rQC®) system
Communication: Bi-directional input/output
Interfaces: USB, Bluetooth.
Memory Capacity: Up to 50,000 patient results

Mode of Opertion: Continuous
Ambient Temperature: 10~30℃(50–86 ºF), indoor use.
Power Requirements: 24 VA
Main Supply Voltage: 100-240 volts AC, 50-60 Hz.
Humidity: 40%~85%
Power Bank: Capable