Chemistry Analyzer Celercare M5

Celercare delivers solutions meeting the clinical need for quick and accurate test results delivered where needed, when needed, improving the efficiency of operations and providing a flexible, long-term solution.

Sales Support

international_sales@mnchip.com
WhatsApp: +86 181 0216 7085

Feature & Benefit

Reliable lab-accurate results
The system delivers fast and reliable lab-accurate results and is intended for professional use in a clinical laboratory setting or at point-of-care locations. After extensive correlation studies, the accuracy, precision and reproducibility of the MNCHIP chemical analyzer has been proven thoroughly. Many devices have been installed not only in clinics but also in most respected hospitals nationwide and more.
Real-time Quality Control
All MNCHIP devices contain a highly efficient onboard quality control system (RQC). It continually monitors the disc function and reagent quality to ensure optimal test performance. Reduce errors with real-time QC and eliminate carryover contamination with single-use panels to ensure meaningful, comparable results with full traceability.
Multiple hospital information system compatibility
The MNCHIP management platform is designed for hospital and laboratory information systems, including HIS, LIS, HR, LMS and EMR. Simplify and standardize work processes and reduce the workload of employees.

Three simple steps for fast, efficient performance.
Easy and safe operation, three simple steps for fast, efficient performance. Celercare M is designed to simplify your workflow with ease of use, flexibility and throughput, so you can rededicate staff to undertake value-added tasks.
Little to no maintenance
The equipment specially designed for the Chinese Space Station has first-class stability and high reliability, and requires almost no maintenance. The use of xenon lamps as the light source has a theoretical working time of decades.

Single-use multi-test panel including chemistry, electrolyte, immunoassay and more.
The tests menu of 33 parameters including chemistry, electrolyte, and immunoassay is the broadest of any point-of-care analyzer. With the efforts of our customer-oriented R&D team, the test parameters will continue to be expanded.
From most respected Hospitals to the Primary Care around you
Can be widely used in Primary Care, Emergency, ICU, Mobile practitioners, Pediatrics, Oncology, Hospitals, Government & Military, Research & Other.
Deliver real-time care for enhancing patient satisfaction
Caregivers can perform a complete panel of up to 13 chemistry tests on-site in about 8~12 minutes. Seconds of hands-on time, minutes for treatment solution. Provide clients with immediate answers during their visit and save technician time with load-and-go efficiency.

Build in printer
Build in Printer, automatically print reports.

Better visual and operation experience
Better visual experience and easier to use capacitive 8.4-inch touchscreen with a more comfortable user interface.

Reagent

Born from space technology, MNCHIP reagent disc is a completely self-contained disposable chemistry panel designed to meet various testing needs. Just 3 drops of whole blood are required to deliver up to 17 precise results.

TP ALB GLO* ALB/GLO* ALT AST TBIL DBIL IBIL* UA CRE UREA GLU TG CHOL HDL-C LDL-C*

AST CK CK-MB LDH α-HBDH UA CRE GLU AMY K+ Na+ Cl- CO2

ALB UA CRE UREA Ca2+ P CO2

TP ALB GLO* ALB/GLO* ALT AST GGT ALP TBIL DBIL IBIL*

AST CK CK-MB LDH α-HBDH

K+ Na+ Cl- Ca2+ P Mg2+ CO2

GLU TG CHOL HDL-C LDL-C* GSP

GLU TG CHOL HDL-C LDL-C* HCY

CRE UREA GLU AMY K+ Na+ Cl- CO2

TP ALB GLO* ALB/GLO* ALT AST GGT TBIL CRE UREA GLU

* Calculated test value
# Coming soon
1 Test/Disc 10 Discs/Box

Step

Add sample & diluent

100 μl whole blood, serum or plasma, and 430 μl diluent.

Insert disc

walk-away operation, self calibrates with every test run.

Read results

build in printer, automatically print reports.

Technology

Our microfludic based blood chemistry device was derived from aerospace technology, which is also used in today’s aerospace industry. After five years of rigorous ground testing, Pointcare M will be installed on the Chinese space station launched in 2022 to provide daily blood chemistry tests for astronauts in orbit.

The analyzer is a portable spectrophotometer. The optical system consists of a xenon arc stroboscopiclamp and a beam-splitter/detector capable of reading nine wavelengths. A heater maintains the disc at 37±0.2°C during the reaction portion of the analysis. The reagent disc is developed based on microfluidic technology. It is an 8 cm diameter consumable containing all the required diluent and dry reagents to perform a panel of tests. The disc contains 30 cuvettes that will be filled with diluted plasma or diluent. The cuvettes have different pathlengths to accommodate different reagent sensitivities and analyte concentrations. Pre-measured, lyophilized reagent beads for each chemistry in the panel are placed in the cuvettes at the time of manufacture. To perform a panel of tests, the operator applies around 100μl whole blood directly into a disc. Using centrifugal and capillary forces, the disc meters the required amount of blood, separates the red cells, meters the plasma, meters the diluent, mixes the fluids, distributes the fluid to the reaction cuvettes and mixes the reagents and the diluted plasma in the cuvettes. The analyzer monitors the reactions simultaneously using nine wave-lengths, calculates the results from the absorbance data, and reports the results on the screen and on a convenient thermal roll-tape printer.

Specification

Dimensions: 260mm (L)*230mm (W)*320mm (H)
Weight: 5.5 kg (12.13 lbs)

Sample Type: Lithium heparin, whole blood, serum or plasma.
Sample Size: 0.1cc (100 µl)
Test Time: 8-12 minutes

Quality Control Features: Built-in real-time Quality Control (rQC®) system
Communication: Bi-directional input/output
Interfaces: WIFI, USB, Bluetooth, LIS/EMR capable.
Memory Capacity: Up to 50,000 patient and quality control results.

Consumables: 7.8cm in diameter and 0.68cm thick, single-use, self-contained plastic chemistry reagent discs. Each disc contains all reagents needed to perform a panel of tests on a single sample.

Data Input Display: 8.4 inch capacitive touchscreen
Print Report: Built in thermal printer, External Printer via MNCHIP Medical Data Management Platform/LIS/EMR etc.
Mode of Opertion: Continuous
Ambient Temperature: 10~30℃(50–86 ºF), indoor use.
Power Requirements: 120 VA
Main Supply Voltage: 100-240 volts AC, 50-60 Hz.
Humidity: 40%~85%
Reaction Temperature: 37℃±0.2℃
Measurement Principles: Spectrophotometry, Turbidimetry.

Contact Us